These endpoints can be used in troubleshooting.
Note |
---|
In the Windows installation also the actuator shutdown endpoint is exposed in order to stop the Accounting Service running as a Windows service.
|
...
- Credentials are explicitly set in the
win32.config/unix.config
file:accounting.actuator.username
/accounting.actuator
.password Password is left empty and thus generated during the SSO installation process by the setup script and you can check the values either from
win32.config/unix.config
file:accounting.actuator.username
/
oraccounting.actuator
.passwordconfig/accounting-install.properties
file:spring.security.user.name
/spring.security.user.password
See also Accounting Service security and SSO Installation Accounting Service settings.
Health endpoint detailed information
...
Code Block | ||
---|---|---|
| ||
{ "status": "UP", "components": { "db": { "status": "UP", "details": { "database": "PostgreSQL", "validationQuery": "isValid()" } }, "diskSpace": { "status": "UP", "details": { "total": 1013310287872, "free": 786584629248, "threshold": 10485760, "exists": true } }, "eventReceiver": { "status": "UP" }, "jms": { "status": "UP", "details": { "provider": "ActiveMQ" } }, "livenessState": { "status": "UP" }, "ping": { "status": "UP" }, "readinessState": { "status": "UP" } }, "groups": [ "liveness", "readiness" ] } |
In case of failure some troubleshooting information an error message is shown, see Troubleshooting Accounting Service / Sample health check in an error case.
...